Bangladesh Fire Rated Doors for Hospitals

Bangladesh Fire Rated Doors for Hospitals

Plain flush fire doors GH fire rated door lowes Features : fire rated up to 3 hours with WHI UL FM label applied . all of doors are designed and fabricated under SDI requirements. 1 3/4" thickness (44.5mm),non-handed assemble with reversible hinge shim parts. fire rated...
Send Inquiry
Description
Technical Parameters

Malaysia fire exit door supplier

 

Bangladesh fire rated doors for hospitals

Malaysia fire exit door supplier

 

GH fire froop steel double door features :

fire rated up to 3 hours with WHI UL FM label applied .

all of doors are designed and fabricated under SDI requirements.

1 3/4" thickness (44.5mm),non-handed assemble with reversible hinge shim parts.

 

fire rated wire glass or louver option for vision lites .

all materials is approved in accordance with NFPA ASTM and other standards .

steel stiffener, hardware preparations and reinforcement are conformed with ANSI standards .

 

GH fire froop steel double door technical data :

Brand

Golden House (GH)

Standard

UL 10(b),UL 10(c) /NFPA/ASTM /UBC7-2

Certifications

INTERTEK(WHI),FM,UL

Fire rated time

45min,90min,up to 180 min

Door Size (single)

standard width up to 4'0"(1200mm ) Height up to 8'0"(2440mm);

customized size is available .

Leaf thickness:1 3/4" standard ( 44.5mm )

Frame jamb depth:100-300mm

Door size (Double)

Maximum size is 8'x8'(2440x2440mm)

Door leaf sheet

20Ga-18Ga (1.0/1.2mm).customized level is available

Door frame sheet

16Ga.(1.5mm) ,customized level is available

Opening

swing /inward or outward

Type

2panel/6panel/flush panel/vision lite /louver

Material of leaf and frame

cold roll steel or Galvanized Steel or Galvannealed Steel

Filling material

Honeycomb,Polystyrene,Mineral Fire Board

Surface finish

factory Primer /finsih paint/power coated/wood grain finished

Color

RAL color system or be customized as well

Application

Suitable for building project,business,home decoration (Office,hotle,church,home and so on )

Packing

in wooden case or steel pallet package

 

detail 3

 

 

detail (4)

detail (5)

Malaysia fire exit door supplier

 

Fire exit doors are required to be suited for the various type of walls as below :

Frame and Hardware must also carry the appropriate fire label

 

Door fire RatingWall RatingDescription and Use
3 Hour 4 HourThe openings are in wall that separating buildings or dividing a single building into designated fire areas.doors for this openning are required at 3 hours fire rating.
1-1/2 Hour 2 HourOpenings are used in enclosures of vertical communication or egress through buildings. theste could be stairwells or elevator shafts. They also are in boiler rooms and in exterior walls that have the potential for severe fire exposure from the outside of the building.

3/4 Hour

(45 Minutes)

1 HourFor use on the openings are in corridors and room partitions. A door with this rating may also be used in the exterior wall which are subject to moderate fire exposure from the outside of the building.

1/3 Hour

(20 Minutes)

1 HourThese openings are in corridors or interior partitions where this fire rating is required .

 

detail (8)

 

 

Malaysia fire door frames

Frame used in masonry walls maybe used with a maximum 3-hour fire door while frame used in drywall stud walls are intended to be used with a maximum 1-1/2-hour fire door. consulting with your door frame manufacturers listings for fire door frames than can be used in drywall stud walls with a maximum 3-hour ratings.

 

detail (9)

Hot Tags: bangladesh fire rated doors for hospitals, China bangladesh fire rated doors for hospitals suppliers, manufacturers, factory, insulated metal door, transom metal door, swinging metal door, single metal door, hurricane proof metal door, polished metal door

正在输入中...

Your name
E-mail
Phone/WhatsApp
Message