Tel: +86 0411 84313423

Search

Home > News > Content
Fire Rated Door Recondition
Oct 30, 2018

Door clearances at the door edge of the door frame (Wood Door), on the pull side of the door, do not exceed clearances listed in 4.8.4 (the clearance under the bottom of the door shall be a maximum of 3/4") and 6.3.1 (top & edges 1/8") Metal door (top & edges up to 3/16").

The self-closing device is operational; that is, the active door completely closes when operated from the full open position.

If a coordinator is installed, the inactive leaf closes before the active leaf.

Latching hardware operates and secures the door when it is in the closed position.

Auxiliary hardware items that interfere or prohibit operation are not installed on the door or frame.

No field modifications to the door assembly have been performed that void the label.

Gasketing and edge seals, where required, are inspected to verify their presence and integrity.