90 Min Stell Fire Rated Doors

90 Min Stell Fire Rated Doors

Feature High definition embossed panels style Factory-applied Epoxy paintsprimer or finfished painting (RAL color options) Fire-rated up to 45/90 Mins with WHI(intertek) label applied (optional)
Send Inquiry
Description
Technical Parameters

S1

Brief Introduction

 

The 2-panel door designed perfectly for applications on more traditional looking style without sacrificing the durability of standard commercial metal security home door. our heavy duty 1-panel steel door is an ideal solution for building, apartment, hotel and motel entry doors and high-end residential buildings.

Heavy Duty 20/18-Gauge A-40/60 Galvanized or galvaneal Steel

Insulated Polystyrene/Honey comb Core (Energy Efficient) filling.

Ideal for Exterior and Interior building Applications.

product-800-800

 

 

GH Steel Fire Door Technical Data :

 

Door material

A40 Galvanized steel or galvanealed .Heavy Duty, SDI Level 2 –( 1.1mm)18-Gauge Steel Face Sheets for doors ,(1.4mm) 16 gauge for frame – (16 Ga. 20 Ga. Available)

Core

Honeycomb Core or Polystyrene Core mineral fireboard /rock wool

Thickness

1-3/4"(44.5mm )AS Standard

Handing

Non-Handed Design; Reversible Hinge Plates

Sizes

Standard Widths up to 4'0"(1220mm), Heights to 8'0"(2440mm) for single ,double will be 8'0" by 8'0"(2400*2400mm),other sizze customized available

Reinforcements

Heavy Gauge steel for Door Closer and Hinge, Lock Reinforcements

Channels

16-Gauge Inverted Top and Bottom Channels, Optional Flush Top Cap

Door Finish

Gray Primer/Finish Paint/powder coating /wood grain finished

Standard Preps

161 (cylindrical lock), 86 Edge (mortise lock), RPD (Panic Bar Reinforced)

Optional Preps

Exit Device Trim, Deadbolts, Card Locks

Fire-Rating

Optional – WHI 90 Mins Fire-Rating, Positive Pressure and "S" Smoke included

 

 

 

 

S5

S6

Fire-Rated doors are required to be suited for the various type of walls as below :

Frame and Hardware must also carry the appropriate fire label

2 Hour1 Hour
Door fire Rating Wall Rating Description and Use
3 Hour 4 Hour The openings are in wall that separating buildings or dividing a single building into designated fire areas.doors for this openning are required at 3 hours fire rating.
1-1/2 Hour 2 Hour Openings are used in enclosures of vertical communication or egress through buildings. theste could be stairwells or elevator shafts. They also are in boiler rooms and in exterior walls that have the potential for severe fire exposure from the outside of the building

3/4 Hour

(45 Minutes)

1 Hour For use on the openings are in corridors and room partitions. A door with this rating may also be used in the exterior wall which are subject to moderate fire exposure from the outside of the building.

1/3 Hour

(20 Minutes)

1 Hour These openings are in corridors or interior partitions where this fire rating is required

 

S8