american standard entrance doors blueTechnical Data:
Brand | Golden House (GH) |
Standard | UL 10(b),UL 10(c) /NFPA/ASTM /UBC7-2 |
Certifications | INTERTEK(WHI),FM,UL |
Fire rated time | 45min,90min,up to 180 min |
Door Size (single) | standard width up to 4'0"(1200mm ) Height up to 8'0"(2440mm); customized size is available . |
Leaf thickness:1 3/4" standard ( 44.5mm ) | |
Frame jamb depth:100-300mm | |
Door size (Double) | Maximum size is 8'x8'(2440x2440mm) |
Door leaf sheet | 20Ga-18Ga (1.0/1.2mm).customized level is available |
Door frame sheet | 16Ga.(1.5mm) ,customized level is available |
Opening | swing /inward or outward |
Type | 2panel/6panel/flush panel/vision lite /louver |
Material of leaf and frame | cold roll steel or Galvanized Steel or Galvannealed Steel |
Filling material | Honeycomb,Polystyrene,Mineral Fire Board |
Surface finish | factory Primer /finsih paint/power coated/wood grain finished |
Color | RAL color system or be customized as well |
Application | Suitable for building project,business,home decoration (Office,hotle,church,home and so on ) |
Packing | in wooden case or steel pallet package |


Fire-Rated doors are required to be suited for the various type of walls as below :
Frame and Hardware must also carry the appropriate fire label
| Door fire Rating | Wall Rating | Description and Use |
| 3 Hour | 4 Hour | The openings are in wall that separating buildings or dividing a single building into designated fire areas.doors for this openning are required at 3 hours fire rating. |
| 1-1/2 Hour | 2 Hour | Openings are used in enclosures of vertical communication or egress through buildings. theste could be stairwells or elevator shafts. They also are in boiler rooms and in exterior walls that have the potential for severe fire exposure from the outside of the building. |
3/4 Hour (45 Minutes) | 1 Hour | For use on the openings are in corridors and room partitions. A door with this rating may also be used in the exterior wall which are subject to moderate fire exposure from the outside of the building. |
1/3 Hour (20 Minutes) | 1 Hour | These openings are in corridors or interior partitions where this fire rating is required . |