Commercial Interior Fire Rated Steel Door

Commercial Interior Fire Rated Steel Door is the most popular and basic fire doors. This commercial interior steel door price also is very competitive. The door's painting is from Japan, anti-rust function is very nice.There are a lot of colors you can choose,all the RAL colors are available.
Brand | Golden House | |
Standard | UL 10(b),UL 10(c) | |
Certifications | INTERTEK,FM,UL | |
Fire rated time | 60min,90min,up to 180 min | |
Door Size (single) | Width not beyond 1200mm | |
Height not beyond 2800mm | ||
Leaf thickness:45mm | ||
Frame thickness:100-300mm | ||
Door size (Double) | Maximum size is 8'x8'(2400x2400mm) | |
Door leaf sheet | 20Ga-18Ga (10/12mm) | |
Door frame sheet | 16Ga.(1.5mm) | |
Opening | Left hand,Right hand,Left hand reverse,Right hand reverse(90 degree) | |
Surface finish | Primer paint/finsih paint/power coated | |
Design | Single/Doule Door | |
2panel/6panel/flush panel/vision/louver/glass | ||
Frame depth | 120mm-240mm | |
Material of leaf | CRS or Galvanized Steel or Galvannealed Steel | |
Material of frame | CRS or Galvanized Steel or Galvannealed Steel | |
Filling material | Honeycomb,Polystyrene,Mineral Fire Board | |
color | RAL color system or be customized as well | |
Application | Suitable for building project,business,home decoration(Office,hotle,church,home and so on ) | |
Packing | in wooden or steel pallet with hand box package | |
Accessories | Hinges | UL listed ball bearing or spring hinges |
Lock | UL cylinder,mortise,panic bar,magnetic lock | |
Handle | Brushed finishing,SS201,SS304 ,SS316 | |
Rubber seal | Foreproof rubber seal | |
Door closer | UL listed closer,concealed closer | |
Glass/Vision | UL listed wire glass or tempered glass | |
Louver | Louver/fire rated louver | |
Other hardwares | Customized | |




Fire-Rated doors are required to be suited for the various type of walls as below :
Frame and Hardware must also carry the appropriate fire label
| Door fire Rating | Wall Rating | Description and Use |
| 3 Hour | 4 Hour | The openings are in wall that separating buildings or dividing a single building into designated fire areas.doors for this openning are required at 3 hours fire rating. |
| 1-1/2 Hour | 2 Hour | Openings are used in enclosures of vertical communication or egress through buildings. theste could be stairwells or elevator shafts. They also are in boiler rooms and in exterior walls that have the potential for severe fire exposure from the outside of the building. |
3/4 Hour (45 Minutes) | 1 Hour | For use on the openings are in corridors and room partitions. A door with this rating may also be used in the exterior wall which are subject to moderate fire exposure from the outside of the building. |
1/3 Hour (20 Minutes) | 1 Hour | These openings are in corridors or interior partitions where this fire rating is required . |
Hot Tags: commercial interior fire rated steel door, China commercial interior fire rated steel door suppliers, manufacturers, factory, riveted metal door, remarkable metal door, industrial metal door, brand direct marketing conditions hazard sign metal door, top notch metal door, hurricane proof metal door