Commercial Interior Fire Rated Steel Door

Commercial Interior Fire Rated Steel Door

Commercial Interior Fire Rated Steel Door This ul 180 min cinema galvanized steel fire door is the most popular and meeting room fire proof doors. This type the price also is very competitive. The door’s painting is from Japan, anti-rust function is very nice.There are a lot of colors you can choose,all the RAL colors are available.
Send Inquiry
Description
Technical Parameters

Commercial Interior Fire Rated Steel Door

120 mins commercial hotel UL listed FM approved Fire door

Commercial Interior Fire Rated Steel Door is the most popular and basic fire doors. This commercial interior steel door price also is very competitive. The door's painting is from Japan, anti-rust function is very nice.There are a lot of colors you can choose,all the RAL colors are available.

Brand

Golden House

Standard

UL 10(b),UL 10(c)

Certifications

INTERTEK,FM,UL

Fire rated time

60min,90min,up to 180 min

Door Size (single)

Width not beyond 1200mm


Height not beyond 2800mm


Leaf thickness:45mm


Frame thickness:100-300mm

Door size (Double)

Maximum size is 8'x8'(2400x2400mm)

Door leaf sheet

20Ga-18Ga (10/12mm)

Door frame sheet

16Ga.(1.5mm)

Opening

Left hand,Right hand,Left hand reverse,Right hand reverse(90 degree)

Surface finish

Primer paint/finsih paint/power coated

Design

Single/Doule Door


2panel/6panel/flush panel/vision/louver/glass

Frame depth

120mm-240mm

Material of leaf

CRS or Galvanized Steel or Galvannealed Steel

Material of frame

CRS or Galvanized Steel or Galvannealed Steel

Filling material

Honeycomb,Polystyrene,Mineral Fire Board

color

RAL color system or be customized as well

Application

Suitable for building project,business,home decoration(Office,hotle,church,home and so on )

Packing

in wooden or steel pallet with hand box package

Accessories

Hinges

UL listed ball bearing or spring hinges


Lock

UL cylinder,mortise,panic bar,magnetic lock


Handle

Brushed finishing,SS201,SS304 ,SS316


Rubber seal

Foreproof rubber seal


Door closer

UL listed closer,concealed closer


Glass/Vision

UL listed wire glass or tempered glass


Louver

Louver/fire rated louver


Other hardwares

Customized

door core

detail 4

detail 6-2

lable

Fire-Rated doors are required to be suited for the various type of walls as below :

Frame and Hardware must also carry the appropriate fire label

 

Door fire RatingWall RatingDescription and Use
3 Hour 4 HourThe openings are in wall that separating buildings or dividing a single building into designated fire areas.doors for this openning are required at 3 hours fire rating.
1-1/2 Hour 2 HourOpenings are used in enclosures of vertical communication or egress through buildings. theste could be stairwells or elevator shafts. They also are in boiler rooms and in exterior walls that have the potential for severe fire exposure from the outside of the building.

3/4 Hour

(45 Minutes)

1 HourFor use on the openings are in corridors and room partitions. A door with this rating may also be used in the exterior wall which are subject to moderate fire exposure from the outside of the building.

1/3 Hour

(20 Minutes)

1 HourThese openings are in corridors or interior partitions where this fire rating is required .

Hot Tags: commercial interior fire rated steel door, China commercial interior fire rated steel door suppliers, manufacturers, factory, riveted metal door, remarkable metal door, industrial metal door, brand direct marketing conditions hazard sign metal door, top notch metal door, hurricane proof metal door