Commercial Office Door Fire Proof

Commercial Office Door Fire Proof

commercial office door fire proof
Send Inquiry
Description
Technical Parameters

 

product-750-524

1

GH Steel Fire Door Features :

fire rated up to 3 hours with WHI  UL  FM label applied .

all of doors are designed and fabricated under SDI requirements.

1 3/4" thickness (44.5mm),non-handed assemble with reversible hinge shim parts.

fire rated wire glass or louver option for vision lites .

all materials is  approved  in accordance with NFPA  ASTM and other standards .

steel stiffener, hardware preparations and reinforcement are conformed with ANSI standards .

 

 

Packing and Transport

2

He3d18e601c6a48b6aac1980d5c572f85i_720x720.jpg

This is commercial office door fire proof

3

 

Los Angeles distribution center : Vancouver distribution center:

Address:14300 Alondra Blvd. La Mirada, CA. 90638 Los Angeles,USA

Tel: 714 562 8808

Vancouver distribution center:

Address: unit 111 1533 Broadway Port Coquitlam,BC. V3C 6P9 Vancouver,Canada

Tel: 604 475 6679

4

GH Steel Fire Door Technical Data :

Brand Golden House (GH)
Standard UL 10(b),UL 10(c) /NFPA/ASTM /UBC7-2
Certifications INTERTEK(WHI),FM,UL
Fire rated time 45min,90min,up to 180 min
Door Size (single)

 standard width up to 4'0"(1200mm ) Height  up to 8'0"(2440mm);      customized size is available .         

Leaf thickness:1 3/4" standard ( 44.5mm )
Frame jamb depth:100-300mm
Door size (Double) Maximum size is 8'x8'(2440x2440mm)
Door leaf sheet 20Ga-18Ga (1.0/1.2mm).customized level is available
Door frame sheet 16Ga.(1.5mm) ,customized level is available
Opening swing /inward or outward
Type 2panel/6panel/flush panel/vision lite /louver
Material of leaf and frame cold roll steel or Galvanized Steel or Galvannealed Steel
Filling material Honeycomb,Polystyrene,Mineral Fire Board
Surface finish factory Primer /finsih paint/power coated/wood grain finished 
Color RAL color system or be customized as well
Application Suitable for building project,business,home decoration (Office,hotle,church,home and so on )
Packing in wooden case or steel pallet package

5

6

Fire-Rated doors are required to be suited for the various type of walls as below :

Frame and Hardware must also carry the appropriate fire label

Door fire Rating Wall Rating Description and Use
3 Hour  4 Hour The openings are in wall that separating buildings or dividing a single building into designated fire areas.doors for this openning are required at 3 hours fire rating.
1-1/2 Hour 2 Hour Openings  are used in enclosures of vertical communication or egress through buildings. theste could be stairwells or elevator shafts. They also are in boiler rooms and in exterior walls that have the potential for severe fire exposure from the outside of the building.

3/4 Hour

(45 Minutes)

1 Hour For use on the  openings are in corridors and room partitions. A door with this rating may also be used in the exterior wall which are subject to moderate fire exposure from the outside of the building.

1/3 Hour

(20 Minutes)

1 Hour These openings are in corridors or interior partitions where this fire rating is required .

7

FIRE DOOR FRAMES

      Frame used in masonry walls maybe used with a maximum 3-hour fire door while frame used in drywall stud walls are intended to be used with a maximum 1-1/2-hour fire door. consulting with your door frame manufacturers listings for fire door frames than can be used in drywall stud walls with a maximum 3-hour ratings.

product-750-269

product-750-848

product-750-662

 

Hot Tags: commercial office door fire proof, China commercial office door fire proof suppliers, manufacturers, factory, stainless steel metal door, stamped metal door, brushed metal door, retro metal door, screwed metal door, single metal door